FLIR IBAC 2
For Support
Please
call (877) 692-2120
or
click here for support
For Service
Submit RMA
Resources:
- IBAC 2 Datasheet
- Download
Specifications
System Overview
- Data Storage
- Internal 2 GB MicroSD memory card; stores over 1 yr of data
- Training Requirements
- < 2 hrs
Environmental
- Operating Humidity
- 5% to 95%, non-condensing
- Operating Temperature
- -5 to 125 °F (-20 to 50 °C)
- Storage Temperature
- -40 to 160 °F (-40 to 70 °C)
Physical Features
- Dimensions (L x W x H)
- 9.5 x 6.5 x 9.0 in (24.0 x 16.5 x 22.9 cm) - without battery; DFU Collector: 3.5 x 3 in (H x Diameter) 8.9 x 7.6 cm; C100 Collector: 4.5 x 5.5 in (H x Diameter) 11.4 x 14 cm
- Weight
- 7.5 lbs (3.4 kg); DFU Collector: 1.3 lbs (0.6 kg); C100 Collector: 3.0 lbs (1.4 kg)
- Enclosure & Protection
- Aluminum, IP66 weatherproof
Power
- Battery Specs
- Li-ion BB 2590 military battery; up to 14 hrs runtime; charge < 4 hrs
- Cold Start Time
- < 5 mins
- Input Voltage
- 100-240 VAC (adapter supplied); 18-36 VDC
- Power Consumption
- DFU Collector: 60 watts; C100 Collector: 60 watts
Sampling & Analysis
- Collection Media
- DFU Collector: Dry sampling - polyester felt filters (47mm diameter, 1 micron); C100 Collector: Wet sampling - buffer rinse fluid provided in premeasured vials
- Max Flow Rate
- DFU Collector: 100 L/min; C100 Collector: 200 L/min
- Particle Size
- DFU Collector: 1 to 10 microns; C100 Collector: 1 to 10 microns
- Sample Collection
- Integrated with DFU or C100 sample collector (see below)
- Sample Introduction
- Airborne particles; triggered aerosol sample collector
- Sample Phase
- Aerosol; flow rate 4.0 L/min (0.14 ft3 /min)
- Sample Recovery
- DFU Collector: Particle extraction from filter performed in vial with liquid buffer; C100 Collector: Manual liquid rinse performed at collector, yields 6mL of liquid
- Sampling & Analysis
- Continuous sampling 24/7/365; indoor/outdoor alarm settings; analysis time configurable down to 1 second
- Sampling Method
- DFU Collector: Dry collection; C100 Collector: Wet or dry collection
- Sensitivity
- < 100 particles/L of air
- Threats
- Spores, vegetative bacteria, viruses, and toxins; particle size: 0.7 – 10 microns
System Interface
- Communication
- Ethernet, RS-232; optional embedded wireless (900MHz or 2.4GHz)
- Output
- Particle data, sensor diagnostics, bio-alarm, and fault
- Display and Alerts
- On-board LED for visual indication; full display via software on external computer
Technology
- Technology
- UV Laser Induced Fluorescence (LIF)