Overview:
Registration
I'm trying to register my FLIR product but I recieve an error that the serial number is not found. What is the reason?
Read the StoryResources:
Specifications
Overview
- Detector Type
- FLIR Indium Antimonide (InSb)
- Dynamic Range
- 14-bit
- IR Resolution
- 320 x 240 pixels
- Mounting
- Standard, 1/4"-20
- Spectral Range
- 3.2 – 3.4 µm
- Zoom
- 1-8x continuous digital zoom
- Hazardous Location Compliance
- ATEX/IECEx, Ex ic nC op is IIC T4 Gc II 3 G ANSI/ISA-12.12.01-2013, Class I Div 2 CSA 22.2 No. 213, Class I Div 2
Environmental
- Ambient temperature range
- -20°C to 40°C (-4°F to 104°F) (Certification range for explosive atmospheres)
- Encapsulation
- IP 54 (IEC 60529)
- Operating Temperature Range
- –20°C to 50°C (–4°F to 122°F)
- Shock & Vibration
- 25 g (IEC 60068-2-27) / 2 g (IEC 60068-2-6)
- Standard Temperature Range
- –20°C to 350°C (–4°F to 662°F)
- Storage Temperature Range
- –30°C to 60°C (–22°F to 140°F)
Imaging & Optical
- Automatic Image Adjustment
- Continuous/manual, linear, histogram
- Camera f-number
- f/1.5
- Color palettes
- Iron, Gray, Rainbow, Arctic, Lava, Rainbow HC
- Detector Pitch
- 30 µm
- Focus
- Manual
- Frame Rate [Full Window]
- 60 Hz
- Global Positioning System [GPS]
- Location data stored with every image
- Image Modes
- IR image, visual image, High Sensitivity Mode (HSM)
- Sensor Cooling
- Stirling Microcooler (FLIR MC-3)
- Image Analysis
- 10 spotmeters, 5 boxes with max./min./average, profile, delta temperatures, emissivity & measurement corrections
- Non-Radiometric IR Video
- MPEG4 (up to 60 min./clip) to memory card
- On Camera Display
- Widescreen 800 x 480 pixel LCD Tiltable 800 × 480 pixel OLED viewfinder
- Radiometric IR Video
- 15 Hz direct to memory card
- Visual Image
- 3.2 MP from integrated visible camera Can be automatically associated with corresponding non-radiometric IR video
- Visual Video
- MPEG4 (25 min./clip) to memory card
Measurement & Analysis
- Accuracy
- ±1°C (±1.8°F) for temperature range (0°C to 100°C, 32°F to 212°F) or ±2% of reading for temperature range (>100°C, >212°F)
- NETD
- <15 mK @ 30°C (86°F)
Power
- Battery type
- Rechargeable Li-ion battery
- External Power Operation
- AC adapter 90-260 VAC, 50/60 Hz or 12 VDC from a vehicle