Overview:
Instructions
Does FLIR offer an SDK to control and get video stream from the FLIR IR cameras?
Learn moreResources:
- FLIR Security Supported 3rd Party Platforms
- Download
Specifications
Overview
- Detector Type
- Long-Life, Uncooled VOx Microbolometer
- Dimensions (L x W x H)
- 233.68 × 116.84 × 104.14 mm (9.2 × 4.6 × 4.1 in) w/o sun shield; 274.32 × 137.16 × 111.76 mm (10.8 × 5.4 × 4.4 in) w/ sun shield
- Focus Range
- Athermalized, focus-free
- Zoom
- Continuous E-zoom, up to 4X
Connections & Communications
- Composite Video NTSC or PAL
- Yes; Hybrid system with IP & Analog video
- Ethernet
- Yes
- External Analytics Compatible
- Yes
- Network APIs
- Nexus SDK for comprehensive system control and integration, Nexus CGI for http command interfaces ONVIF Profile S
- Video Over Ethernet
- Two independent channels of H.264, MPEG-4 & M-JPEG (see website for full details)
Environmental
- Humidity
- 0-95% relative
- IP Rating
- IP66 & IP67
- Operating Temperature Range
- -50°C to 70°C (continuous operation) -40°C to 70°C (cold start)
- Shock
- MIL-STD-810F "Transportation"
- Storage Temperature Range
- -55°C to 85°C
- Vibe
- IEC 60068-2-27
Imaging & Optical
- Image Uniformity Optimization
- Automatic Flat Field Correction (FFC) Thermal and Temporal Triggers
- Spectral Range
- 7.5 µm to 13.5 µm
- Thermal AGC Modes
- Auto AGC, Manual AGC, Plateau Equalization AGC, Linear AGC, Auto Dynamic Detail Enhancement (DDE), Max Gain Setting
- Thermal AGC Region of Interest
- Default, Presets and User definable to insure optimal image quality on subjects of interest
Measurement & Analysis
- Measurement Accuracy
- +/-5°C or 5% of reading
- Measurement Range
- -10°C to 110°C
Power
- Input Voltage
- 11-44 VDC (no lens heaters), 16-44 VDC (w/lens heaters), 14-32 VAC (no lens heaters), 16-32 VAC (w/lens heaters), PoE (IEEE 802.3af-2003), PoE+ (IEEE 802.3at-2009)
- Power Consumption
- 24 VDC 5 W nominal, 21 W peak (w/heaters), 24 VAC, 8 VA nominal, 29 VA peak (w/heaters), Approvals, FCC Part15, Subpart B, Class B, CE: EN 55022 Class B
- Surge Immunity on AC Power Lines
- EN 55024: 2010 and 55022: 2010 to 4.0kV on AC aux power lines
- Surge Immunity on Signal Lines
- EN 55024: 2010 and 55022: 2010 to 4.0kV