Specifications
System Overview
- Application Time
- Handheld Applicator: 30 seconds / m2 Backpack Applicator: < 3 minutes / HMMWV Cart-Based Applicator: <3 minutes / HMMWV
- Training Requirements
- < 1 hour; no special skills required
Environmental
- Cold Weather Additive
- Lowers operating temp of nerve agent and training formulations to -4 °F (-20 °C)
- Life Expectancy
- 12 hr operational pot-life once prepared; 8 hrs at 104 °F (40 °C ); shelf-life >3 yrs when stored below 77 °F (25 °C)
- Operating Conditions
- The response must be read under white light (standard) or UV-light (fluorescent additive and forensic version)
- Operating Humidity
- 0-100%
- Operating Temperature
- Nerve agent and training formulation: 32 to 113 °F (0 to 45 °C); blister agent formulation: 23 to 113 °F (-5 to 45 °C)
- Storage Temperature
- Store at room temp out of direct sunlight; product expiration is indicated by temp-time indicator on packaging
- Waste
- Dispose in accordance with local policies for non-hazardous aqueous waste
- Water Source
- Handheld applicator: water included; large-scale consumable:tap water ≤250 ppm calcium carbonate and treated for chlorine (chlorine treatment included)
Physical Features
- Setup Time
- Handheld Applicator: < 5 minutes Large-Scale Consumable Kit: < 15 minutes
- Spray Volume
- Handheld Applicator: 0.5L Large-Scale Consumable Kit: 2 Gal
- Surface Compatibility
- Large variety of materials, won't degrade sensitive surfaces
- Surface Coverage
- Handheld Applicator: 5-7m2 Large-Scale Consumable Kit: 75 -12 0m2, 2-3 HMMW Vs
- Weight [Full]
- Handheld Applicator: Max 1.2 lbs (0.54 kg) Large-Scale Consumable Kit: 2.6 lbs (1.2kg)
Power
- Cold Start Time
- < 3 mins
- Power
- Handheld Applicator: N/A Backpack Applicator: Compressed air, 4000 psi SCBA or hand powered versions available Cart-Based Applicator: Compressed air, 4000 psi SCBA, 120 psi compressor, LMTV compatible
Sampling & Analysis
- Sample Introduction
- Spray directly onto surface
- Sample Phase
- Surface-based detection
- Sampling & Analysis
- Detection within 5 mins
- Threats
- Enzyme formulations include: nerve agent (V- & G-series) and blister agent (HD); training disclosure spray also available
System Interface
- Fluorescent Additive
- Enhances visual response of standard spray under challenging lighting conditions or surfaces when used with UV-light
- Display and Alerts
- Colorimetric sensor response; Standard nerve agent and training spray is yellow when applied to a surface and surface changes to red within 5 mins if contaminated; blister agent spray is applied red and changes to yellow if clean but stays red if contaminated; forensic spray is translucent when applied and contamination is visible under UV-light
Technology
- Technology
- Enzymes