Overview:
Trouble Shooting
I have a FLIR A3xx camera but I cannot see the image stream. What is wrong?
Read the StorySystem Requirements
What is the specification of the heater inside the Flir A310f housing?
Read the StoryRegistration
I'm trying to register my FLIR product but I recieve an error that the serial number is not found. What is the reason?
Read the StoryConfiguration
My Ethernet camera (FLIR A3x0/A3x5/A6x5/Ax5) in FLIR Tools does not display a live image but instead shows a rainbow-colored image. How do I fix this?
Read the StorySystem Requirements
What is the recommended airflow pressure for the dust ring attached to the FLIR A310f?
Read the StoryInstructions
Does FLIR offer an SDK to control and get video stream from the FLIR IR cameras?
Learn moreResources:
- Warranty: FLIR International Uncooled Thermal Camera 2-10 Limited Warranty
- Download
Specifications
Overview
- Alarm Functions
- 6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer
- Alarm Output
- Digital Out, log, store image, file sending (ftp), email (SMTP), notification
- Automatic Heater
- Clears window from ice
- Base Mounting
- TBA
- Detector Type
- Focal Plane Array (FPA), uncooled microbolometer
- Difference Temperature
- Delta temperature between measurement functions or reference temperature
- Housing material
- Aluminum
- List of Contents
- Cardboard box, Infrared camera with lens and environmental, housing, FLIR Sensors Manager download card, FLIR Tools & Utilities CD-ROM, Lens cap, Printed documentation, Small accessories kit, User documentation CD-ROM
- Packaging Size
- 534 x 207 x 230 mm (21.0 x 8.1 x 9.1 in.)
- Set-up Commands
- Date/time, Temperature°C/°F
- Size (L x W x H)
- 460 × 140 × 159 mm (18.1 × 5.5 × 6.3 in.)
- Spectral Range
- 7.5–13 µm
- Weight
- 5 kg (11.0 lb.)
- Zoom
- 1–8× continuous, digital, interpolating zooming on images
Connections & Communications
- Digital I/O connector type
- 6-pole jackable screw terminal
- Digital I/O isolation voltage
- 500 VRMS
- Digital I/O supply voltage
- 12/24 VDC, max 200 mA
- Digital input purpose
- Image tag (start/stop/general), Input ext. device (programmatically read)
- Digital Inputs
- 2 opto-isolated, 10–30 VDC
- Digital Output Purpose
- As function of ALARM, Output to ext. device (programmatically set)
- Digital Outputs
- 2 opto-isolated, 10–30 VDC, max 100 mA
- Ethernet
- Control, result and image
- Ethernet Communication
- TCP/IP socket-based FLIR proprietary
- Ethernet Connector Type
- RJ-45
- Ethernet Image Streaming
- 16-bit 320 × 240 pixels @ 7-8 Hz- Radiometric
- Ethernet Power
- Power over Ethernet, PoE IEEE 802.3af class 0
- Ethernet Protocols
- Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
- Ethernet Standard
- IEEE 802.3
- Ethernet Type
- 100 Mbps
- Ethernet Video Streaming
- MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5
- Storage Media
- Built-in memory for image storage
- Video Out
- Composite video output, PAL and NTSC compatible
- Video Connector Type
- Standard BNC connector
Environmental
- Atmospheric transmission correction
- Automatic, based on inputs for distance, atmospheric temperature and relative humidity
- Bump
- 5 g, 11 ms (IEC 60068-2-27)
- EMC
- EN 61000-6-2 (Immunity), EN 61000-6-3 (Emission), FCC 47 CFR Part 15 Class B (Emission)
- Emissivity Correction
- Variable from 0.01 to 1.0
- Encapsulation
- IP 66 (IEC 60529)
- Humidity (Operating and Storage)
- IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)
- Operating Temperature Range
- –25°C to +50°C (–13°F to +122°F)
- Storage Temperature Range
- –40°C to +70°C (–40°F to +158°F)
- Vibration
- 2 g (IEC 60068-2-6)
Imaging & Optical
- Color palettes
- Color palettes (BW, BW inv, Iron, Rain)
- Detector Pitch
- 25 µm
- Detector Time Constant
- Typical 12 ms
- f-number
- 1.3
- Focus
- Automatic or manual (built in motor)
- Image Frequency
- 30 Hz
- Lens Identification
- Automatic
- Video Standard
- CVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)
Measurement & Analysis
- Accuracy
- ±4°C (±7.2°F) or ±4% of reading
- Area
- 10 boxes with max./min./average/position (7 if FLIR Sensors Manager is used)
- External Optics & Windows Correction
- Automatic, based on input of optics/window transmission and temperature
- Isotherm
- 1 with above/below/interval
- Measurement Corrections
- Global and individual object parameters
- Measurement Option
- Measurement Mask / Filter Schedule response: File sending (ftp), email (SMTP)
- Optics Transmission Correction
- Automatic, based on signals from internal sensors
- Reference Temperature
- Manually set or captured from any measurement function
- Reflected apparent temperature correction
- Automatic, based on input of reflected temperature
- Spot Meter
- 10.0
- Thermal Sensitivity/NETD
- < 0.05°C @ +30°C (+86°F) / 50 mK
Power
- External Power Connector Type
- 2-pole jackable screw terminal
- External Power Connector Type [heater]
- 2-pole jackable screw terminal
- External Power Operation
- The camera operates on 12/24 VDC, 9 W max. (allowed range: 10-30 VDC) and heaters on 24 VDC, 25 W max. In total: 34 W.
- External Power Operation [heater]
- 24 VDC, 25 W max.
- Voltage
- Allowed range 10–30 VDC
- Voltage [heater]
- Allowed range 21-30 VDC
Storage Media
- File Formats
- Standard JPEG, 16-bit measurement data included