PathFindIR™ II
Support Center

PathFindIR™ II

Go to Product Details Page

For Support
Please submit a ticket.

For Service
submit RMA.

Overview:
Technical Guidance

How rugged is the PathFindIR II for vehicles?

Read the Story
Technical Guidance

Where do I mount a monitor for PathFindIR II and what type of monitor do you recommend?

Read the Story
Instructions

What is the Export Control Classification Number (ECCN) for PathFindIR?

Read the Story
Technical Guidance

How does FLIR test its thermal camera cores and lenses for sealing to IP67? Is a vacuum test used?

Read the Story
Technical Guidance

Does the PathFindIR II work in fog?

Read the Story
Instructions

How do I talk to and control the PathFindIR?

Read the Story
Technical Guidance

What is the price of a PathFindIR II? Is quantity pricing available?

Read the Story
Technical Guidance

How do I adjust the contrast and brightness of a PathFindIR II?

Read the Story
Technical Guidance

What is the difference between the PathFindIR II and Boson, Quark2, Tau2 cores?

Read the Story
Technical Guidance

What is the influence of the camera temperature on the pixel readings? Can this be corrected by a linear model?

Read the Story
Trouble Shooting

Why does the PathFindIR II image “freeze” every now and then?

Read the Story
Technical Guidance

Are FLIR's OEM products on a GSA Schedule?

Read the Story
Resources:
PathFindIR II - Compatible Electronics
Download
PathFindIR II Quick Start Guide
Download
FLIR PathFINDIR II Datasheet
Download
Specifications
Overview
ECU Dimensions
5.8" × 4.3" × 0.9" (148 × 110 × 24 mm )
ECU Weight
0.7 lb (350 g)
Spectral Band
8-14 microns (LWIR)
Camera Dimensions
2.6" × 3.4" × 3.2" (60 × 86 × 82 mm )
Camera Weight
0.6 lb (300 g)
Connections & Communications
Output
NTSC
Environmental & Approvals
Operating Temperature
-40°C to 80°C
Weather Resistance [Camera]
Hermetically Sealed, Automotive Qualified
Weather Resistance [ECU]
Non-Hermetic; Passenger Compartment mount required
Window
High-Impact Resistant Optic w/ Built-in Automatic Heating Element Replaceable Window
Imaging & Optical
Field of View
24° (h) x 18° (v)
Sealed Design
IP69 rated, hermetically sealed providing extra insurance in all weather conditions
Sensor Type
320 x 240 Uncooled Microbolometer
Power
Power Consumption
2 W (6 W w/heater on) 1.8 A max. system current
Power Requirements
12 VDC