Cart

Added to cart

Go to cart

Your order qualifies for free 2-day shipping and easy returns

SWIR Camera with InGaAs Detector

FLIR A6260

Go to Product Support
product image

The FLIR A6260 SWIR camera offers superior sensitivity and dynamic range paired with the flexibility of customized windowing and integration times. This InGaAs camera is very linear in the 0.9 to 1.7 µm sensing waveband, making it the perfect tool for high temperature thermal measurements and applications that require measuring through standard glass. The A6260 offers control over settings such as integration time, while allowing you to synchronize and trigger to external events and devices.

Sales Contact Contact Sales
  • Crisp, High-Resolution Images

    The 327,680 (640 x 512) pixel detector offers three user-selectable, 75x factor gain states for imaging bright and low-light scenes.

  • Fully Customizable

    Tailor controls to unique applications through customizable integration times, frame rates, synchronization, and triggering.

  • Accurate Temperature Measurement

    Factory or user-calibrate the A6260 to measure temperatures above 400°C when optimized for the 0.6 - 1.7 µm waveband.

Contact Sales

Want more information on this product?

Call 0049 69-950090 0 to speak with a knowledgeable specialist.

Specifications
Resolution
640 × 512
Pixel Size [Square]
15 µm
Spectral Range
0.9 – 1.7 µm
Detector Type
FLIR indium gallium arsenide (InGaAs)
Camera f-number
Variable using lens iris (lens fixed at f/4 with cal)
Frame Rate [Full Window]
Programmable; 0.0015 Hz to 125 Hz (180 Hz burst)
Integration Time
50 µsec to ~full frame (3.2 msec w/factory calibration)
Standard Temperature Range [with band matched optics]
400°C to 1200°C/752°F to 2192°F (ND1)
Optional Temperature Range [with band matched optics]
600°C to 1500°C/1112°F to 2732°F (ND2); 700°C to 2500°C/1292°F to 4532°F (ND3)
Filter Holder [Warm]
Behind lens mount for standard 1-inch diameter filters
Focus
Manual
Imaging & Optical
Available Lenses
16 mm, 25 mm, 35 mm, 50 mm, 100 mm
Camera f-number
Variable using lens iris (lens fixed at f/4 with cal)
Close-up Lenses/Microscopes
No microscopes available
Filter Holder [Warm]
Behind lens mount for standard 1-inch diameter filters
Image Time Stamp
Yes
Integration Time
50 µsec to ~full frame (3.2 msec w/factory calibration)
NEI [Typical]
8.4E9 Photons/sec/cm2 (Low Gain), 2.9E9 photons/sec/cm2 (Med Gain)
Noise Floor [Typical]
Low Gain: 350e, Med Gain: 56e
On Camera Image Storage
None
Overlay
Fixed configuration, can be turned off
Pixel Clock
100 MHz
Pixel Size [Square]
15 µm
Radiometric Data Streaming
Gigabit Ethernet (GigE Vision)
Readout Modes
Asynchronous integrate while read, asynchronous integrate then read
Readout Type
Snapshot
Sensor Cooling
Single Stage TE Cooler, 30C FPA setpoint
Standard Video
SDI
Standard Video Zoom
Automatic, variable
Subwindow Modes
640 x 512, 320 x 256, 160 x 128, flexible centered windowing down to 32 × 4 (steps of 32 columns, 4 rows)
Thermal Sensitivity_NETD [typical]
N/A
Video Modes
SDI: 720p@50/59.9, 1080p@25/29.9
Measurement & Analysis
Ambient Drift Compensation [with factory cal]
Yes
Optional Temperature Range [with band matched optics]
600°C to 1500°C/1112°F to 2732°F (ND2); 700°C to 2500°C/1292°F to 4532°F (ND3)
Standard Temperature Range [with band matched optics]
400°C to 1200°C/752°F to 2192°F (ND1)
General
Size [L x W x H ] w/o Lens
216 × 102 × 109 mm (8.5 × 4.0 × 4.3 in.)
Related Documents
Export Restrictions

Export Restrictions

The information contained in this page pertains to products that may be subject to the International Traffic in Arms Regulations (ITAR) (22 C.F.R. Sections 120-130) or the Export Administration Regulations (EAR) (15 C.F.R. Sections 730-774) depending upon specifications for the final product; jurisdiction and classification will be provided upon request.

FLIR A6260