Explosive atmospheres need to be protected from ignition sources. Selecting equipment and protective systems which meet the requirements of the ATEX Product Regulations or similar regulations is essential. FLIR A310 ex is an ATEX compliant solution, with a thermal imaging camera mounted in an enclosure, making it possible to monitor critical and other valuable assets also in explosive atmospheres. Typical applications for the A310 ex include process monitoring, quality control, and fire detection in explosive locations. Because the FLIR A310 ex is rated IP 67, it can be installed in dusty environments. The Flame-Proof Enclosure "d"prevents any explosion transmission from the inside of the enclosure to the outside
-
Integrated Controller
The integrated controller features several digital I/O channels and sensors for temperature, humidity and pressure. Among other functions, the I/O channels enable the user to switch on/off the camera and the heater via remote control. The access is accomplished through an integrated web interface or Modbus TCP/IP. The integrated controller is equipped with two fber optic and two Ethernet parts. This enables a flexible network integration in star or ring topologies
-
Heater
FLIR A310 ex comes with a heater which effectively prevents fogging and fireezing of the protection window
-
VERIFICATION CERTIFICATE ZELM 12 ATEX 0485 X
The FLIR A310 ex is ATEX-certifed. It can be installed in classifcation zones 1, 2, 21 and 22. The certifcation comprises the whole system, which includes the enclosure, as well as all components inside, such as the thermal imaging camera, heater and integrated controller
Specifications
Overview
- Alarm Functions
- 6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer
- Alarm Output
- Digital Out, log, store image, file sending (ftp), email (SMTP), notification
- Detector Type
- Focal Plane Array (FPA), uncooled microbolometer
- Difference Temperature
- Delta temperature between measurement functions or reference temperature
- Empty Volume
- 5.06 l
- External Dimensions [without sun shield]
- D = 170 mm, L = 408 mm
- Integrated Controller
- 4-port switch with 2 × fiber-optic LC 100Base-FX or 2 × RJ45(10/100) up-links, ring-topology support for reduced cabling effort, 2 × internal temperature sensors, air humidity and pressure sensor, digital output module controllable via Modbus TCP/IP or web interface to enable turning the heater on/off
- IR Resolution
- 320 × 240 pixels
- Packaging Size
- 495 x 370 x 192 mm (19.5 x 14.6 x 7.6 in.)
- Protection Class
- IP67
- Protection Window
- Germanium, double-sided AR Coated, externally with additional hard-carbon layer
- Set-up Commands
- Date/time, Temperature°C/°F
- Spectral Range
- 7.5–13 µm
- Zoom
- 1–8× continuous, digital, interpolating zooming on images
- Contents
- Infrared camera with lens, in explosion-proof housing, cardboard box, Printed documentation, User documentation CD-ROM, Utility CD-ROM
- Housing material & Surface
- Nickel-plated aluminium / Powder coated
Connections & Communications
- Ethernet
- Control, result and image
- Ethernet Communication
- TCP/IP socket-based FLIR proprietary
- Ethernet Configuration
- Pigtail with FC-connector (fiber)
- Ethernet Image Streaming
- 16-bit 320 × 240 pixels @ 7-8 Hz - Radiometric
- Ethernet Medium
- Multi-mode breakout fiber AT-V(ZN)Y(ZN)Y 4G50/125 OM2
- Ethernet Protocols
- Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
- Ethernet Standard
- 100 Mbps / IEEE 802.3
- Ethernet Video Streaming
- MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5
- Length of Ethernet cable
- 4 m (13 ft.)
- Storage Media
- Built-in memory for image storage
- Power Cable & Configuration
- Helukabel 37264 / Pigtail
Environmental
- Ambient temperature range for operation
- –20°C to +40°C (-4°F to 104°F)
- Atmospheric transmission correction
- Automatic, based on inputs for distance, atmospheric temperature and relative humidity
- Emissivity Correction
- Variable from 0.01 to 1.0
- Verification Certificate
- ZELM 12 ATEX 0485 X
Explosion protection-specific
- ATEX certification (version-AXC)
- EX-Protection Gas: II 2G Ex d IIC T6 Gb, EX-Protection Dust: II 2D Ex tb IIC T85° Db
- For use in EX zone
- 1, 2, 21, and 22
- Ignition protection category
- Flame-proof enclosure "d"
- Maximum Surface Temp [temp class T6]
- Maximum 85°C
Imaging & Optical
- Color palettes
- Color palettes (BW, BW inv, Iron, Rain)
- Detector Pitch
- 25 µm
- Detector Time Constant
- Typical 12 ms
- f-number
- 1.3
- Focus
- Automatic or manual (built in motor)
- Image Frequency
- 30 Hz
- Lens Identification
- Automatic
- Minimum Focus Distance
- 0.4 m (1.31 ft.)
- Spatial resolution (IFOV)
- 1.36 mrad with 25° lens
- Field of view (FOV) - Focal Length
- 25° × 18.8° with 18 mm (0.7 in.) lens
Measurement & Analysis
- Accuracy
- ±2°C (±3.6°F) or ±2% of reading
- Area
- 10 boxes with max./min./average/position
- External Optics & Windows Correction
- Automatic, based on input of optics/window transmission and temperature
- Isotherm
- 1 with above/below/interval
- Measurement Corrections
- Global and individual object parameters
- Measurement Option
- Measurement Mask Filter Schedule response: File sending (ftp), email (SMTP)
- Object Temperature Range
- –20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to +662°F)
- Optics Transmission Correction
- Automatic, based on signals from internal sensors
- Reference Temperature
- Manually set or captured from any measurement function
- Reflected apparent temperature correction
- Automatic, based on input of reflected temperature
- Spot Meter
- 10.0
- Thermal Sensitivity/NETD
- < 0.05°C @ +30°C (+86°F) / 50 mK
Power
- Length of Power Cable
- 4 m (13 ft.)
- Maximum Electric Connection Power
- 60 W
- Maximum power of the Additional Heater
- 16 W
- Operating Voltage
- 24 V DC
Storage Media
- File Formats
- Standard JPEG, 16-bit measurement data included
Accessories
Related Documents
Want more information on this product?